Description
Use as a geyser timer or use as timer on a thermosyphon solar system
Clear display of water temperature, time, day, heating mode and malfunction conditions.
Auto or manual heating.
Easy temperature setting to your requirements (30 – 75°C) factory default is 55°C.
Four different temperature settings.
Daily programmable timer with four time settings.
Error conditions alert by warning code E2 to E5 and E7.
Electronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for solar systems expected to reach temperatures above this temperature.
SPECIFICATIONS
Operating voltage 230VAC / 50HZ.
Main relay contact rating 30AMP (Max 4KW).
Operating voltage range 220V – 250V AC.
Temperature display range 0 – 99°C (“-5” when below -5°C “EA” when above 99°C).
High temperature warning above 84°C.
Temperature setting ranges 30 – 75°C (heating water electrically).
Heat failure – when increase at a rate of less than 4°C per hour.
Mechanical thermal cut-out at 90°C. Please note the cut-out temperature for systems expected to reach temperatures above this temperature.
Dry heat detection – empty cylinder.
Temperature tolerance ± 2%.
Temperature differential setting 1°C.
Switching differential 6°C.
Temperature probe failure detection for tank
Temperature probe range for geyser is -30 to + 130°C.
WHAT’S IN THE BOX
1 X Geyserwise TSE1 with Tuya Module